PEX CR
6807-54-009
EX white + RED LED light fixture in Explosion proof housing with four 1/2" NTP threaded holes for EX cable glands (not included)
Installation hazardous areas: Zone 1/2 (Gases) - Zone 21/22 (Dusts)
Classifications GROUP II - Category 2G/2D
II 2 G Ex d IIB+H2 T5 Gb - II 2 D Ex tb IIIC T100°C Dbs)
Lighting features
Primary light
Secondary light
Light source flux
3000 lm
Light fixture flux
2040 lm
52 lm
Light source efficiency
155lm/W
Light fixture efficiency
89lm/W
11 lm/W
Color temperature
Natural Weiß 4000 K
Red; Dominant Wavelength: >619nm; <625nm
Photobiological risk group RG
RG0
RG0
Maintenance of the luminous flux
L90 B50 >60000 h
L70 B50 36000 h
Electrical features
Primary light
Secondary light
Power supply
100/240V~ 50/60Hz
100/240V~ 50/60Hz
Insulation Class
Class I
Class I
Control/dimming system
ON/OFF
ON/OFF
Features LED
MID Power
MID Power
Type of cooling
Passive
Passive
Driver lifetime
110000h
36000h
Driver
Driver Included
Driver Included
Driver type
Costant Current
Costant Voltage
Driver output
1050mA
24VDC
Driver input
100-240V~ 50/60Hz
100/240V~ 50/60Hz
Driver overvoltage protection
Mains surge 4kV; (L/N - PE) 6KV
Mains surge 2Kv
Through wiring
Yes, in the lamp
Yes, in the lamp
Mechanical features
Housing material
Marine grade copper free alluminium
Surface treatment
External epoxy powders
Shock proof MIL-S 901D
Yes
Diffuser / Protective shield
Hight temperature resistant borosylicate glass
Mounting
With stainless steel brackets AISI 316L; fixing with 4 M10 screws
Operating ambient temperature
-30°C / +55°C
Storage ambient temperature
-30°C / +85°C
Dimensions
H: 380 W: 198 D: 136 mm
Others
International standard compliance
EN 60598-1; EN 60598-2-1; IEC 60092-306; IEC 60533; EN 62471 + TR62778; EN50581; EN 60079-0; EN60079-1; EN60079-7; EN60079-28; EN60079-31